01 / SOVEREIGN EDGE COMPUTE

Compute that stays.

NOORD builds on-premise AI inference appliances for European industry. Your models run inside your walls, on your power, under your law. Nothing leaves the site.

Exploded line diagram of the NOORD E-40 rack appliance TOP COVER — SEALED COLD PLATE — DIRECT LIQUID INFERENCE MODULES ×4 NVME 16 TB — ENCRYPTED CHASSIS — 2U / 19″ 483 MM 88.9 MM
FIG. 01 — NOORD E-40, EXPLODED VIEW
  • 01 Top cover — sealed
  • 02 Cold plate — direct liquid
  • 03 Inference modules ×4
  • 04 NVMe 16 TB — encrypted
  • 05 Chassis — 2U / 19″

4.2 kW rack unit

1.9 ms median inference

0 bytes egress

CE / NIS2 / GDPR aligned

02 / THE CONSTRAINT

Some data can't take the trip.

A container terminal generates more sensor data in an hour than it can push to a datacentre in a day. A hospital can't send imaging across a border. A grid operator can't accept 200 ms of round-trip latency on a protection decision.

The cloud is not wrong. It's just somewhere else.

  • 200–400ms

    Typical round trip to the nearest hyperscaler region — before inference begins.

  • 63%

    Of European industrial operators name data residency as the blocker to production AI.

  • €0.09/GB

    Egress, charged every time your own data leaves.

03 / HARDWARE

One rack unit. No dependencies.

NOORD ships a sealed inference appliance, pre-loaded with your models, racked by our field team and maintained under a five-year contract. It needs power, cooling and a network drop. It does not need us.

SPEC — NOORD E-40

Form factor

2U, 19″ rack

Throughput

Up to 340 tokens/s sustained, 7B class

Latency

1.9 ms median · 4.4 ms p99

Draw

4.2 kW peak · 1.6 kW idle

Cooling

Direct liquid — facility loop or self-contained

Storage

16 TB NVMe, encrypted at rest, keys held on site

Network

Air-gap capable. Updates by signed physical media.

Support

5 years, 4-hour on-site across the Benelux

Firmware and model weights are signed and auditable. You can read every line we ship you.

04 / DEPLOYMENTS

Built for floors, not for demos.

  • 04.1

    Ports & terminals

    Crane vision, container OCR and berth scheduling at the quay, where the fibre stops.

    ANTWERP · ROTTERDAM · VLISSINGEN

  • 04.2

    Manufacturing

    Defect detection on the line at frame rate, with weights that never leave the plant.

  • 04.3

    Energy & grid

    Sub-cycle anomaly detection inside the substation, air-gapped from the corporate network.

  • 04.4

    Care & diagnostics

    Imaging models run in the hospital basement. Patient data stops at the door.

61 appliances in production

9 operators

4 countries

0 recorded egress events

05 / NEXT

Tell us what your site can't send.

Our field engineers spend a day on your floor measuring power, thermal headroom and network reality, then tell you honestly whether an appliance is the right answer. Roughly one assessment in four ends with us recommending you don't buy one.